Model | Applicable flow rate sensor | Flow rate measurement range Note 1) | Set flow rate range Note 1) | Minimum set unit Note 1) | Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Note 1) | Note 1)Display units | Accumulated flow range Note 1) | Power supply voltage | Current consumption | Power supply voltage for sensor | Power supply current for sensor Note 2) | Sensor input | -- | Output Note 3)specifications | Hysteresis | Response time Note 4) | Linearity Note 4) | Repeatability Note 4) | Temperature characteristics | Display method | Status LED?s | Resistance | Connection | Material | Weight |
PF2W200/201 | PF2W504/504T- -1 | 0.35 to 4.50 l/min | 0.35 to 4.50 l/min | 0.05 l/min | 0.05 l/pulse | Real-time flow rate | Accumulated flow | 0 to 999999 l, 0 to 999999 gal(US) | 24 VDC (ripple ?10% or less) (With power supply polarity protection) | 55 mA or less (Note including the current consumption of the sensor) | Same as [Power supply voltage] | Max. 110 mA (However, the total current for the 4 inputs is 440 mA maximum or less.) | 1 to 5 VDC (Input impedance: Approx. 800K ) | No. of inputs | Input protection | Switch output(Real-time switch output, accumulated switch output) | Switch output(Real-time switch output, accumulated switch output) | Accumulated pulse output | No. of outputs | Output protection | Hysteresis mode: Variable (can be set from 0), Window comparator mode: Fixed (3-digits) | 1s or less | ?5% F.S. or less | ?3% F.S. or less | ?2% F.S. or less (0 to 50C, based on 25C) | For measured value display: 4-digits, 7-segment LED (Orange) For channel display: 1-digit, 7-segment LED (Red) | Illuminates when output is ON OUT1: Red | Enclosure | Operating temperature range | Operating humidity range | Vibration resistance | Impact resistance | Noise resistance | Power supply / Output connection: 8P connector, Sensor connection: 4P connector (e-con) | Housing: PBT, Display: PET, Backside rubber: CR | 60 g (Except for any accessories that are shipped together) |